| 190 Specifications |
| Power Requirements: |
100 to 240 VAC (50/60 Hz) at 0.4A Max. / 190DC: 10.5 to 30 VDC 1.0A Max. |
Optional Rechargeable
Battery Life: |
80 hours with BLUE backlight (running single load cell)
60 hours with YELLOW backlight (running single load cell)
Battery life will be extended with SLEEP and AUTO-OFF operation set |
| Enclosure Type: |
Thermoplastic IP69K wall or desk-mount |
| Enclosure Size: |
9.4 inch W x 6.4 inch H x 3.7 inch D / 239 mm W x 163 mm H x 93 mm D |
| Operating Environment: |
Temperature: 14 to 104 ºF (-10 to +40 ºC)
Humidity: 90% non-condensing (maximum) |
| Display: |
Six digit, seven segment, 1.0 inch high Backlit LCD |
| Transducer Excitation: |
5.18 VDC |
| Signal Input Range: |
0.5 mV min. to 40 mV max. (with dead load boost) |
| Number of Load Cells: |
6 each, 350 OHM minimum resistance |
| Load Cell Cable Length: |
1500 feet maximum.
30 feet maximum without sense lines
Consult factory for other requirements |
| Division Value: |
1, 2, or 5 x 10, 1, 0.1, 0.01, 0.001 commercial
0 to 99, non-commercial |
Sensitivity:
NON-COMMERCIAL
COMMERCIAL |
0.15 uV/e
0.5uV/e (Class III/IIIL/IIIHD) |
Scale Divisions:
NON-COMMERCIAL
COMMERCIAL |
100 to 240,000
100 to 10,000 (Class III/IIIL/IIIHD) |
| Internal Resolution: |
1 part in 16,777,216 |
| Tare Capacity: |
Scale Capacity |
| Sample Rate: |
1 to 100 samples per second, selectable |
| Auto Zero Range: |
0.5 or 1 through 9 divisions |
| Weighing Units: |
Pounds, Ounces, Kilograms, Grams |
| Keypad: |
Color Coded Capacitive Touch type, 7 keys |
| Standard I/O: |
(1) bi-directional RS232 |