An Overview of Cardinal Scale Load Cell Kits

Load-Cell-Kits-1Cardinal Scale’s USA-made load cell stand kits let you turn almost any vessel or platform into an integrated weighing system. A few basic things need to be considered when choosing the right system. We’ll also discuss the proper installation and setup methods to use.

Whether utilizing beam, tension, or compression cells in either analog or hydraulic configurations, Cardinal load cell kits give you flexible options to help solve many weighing applications.

To determine the total capacity of the system, you first need to know the total weight of the structure that the load cell stands will be supporting (dead load). Add the anticipated maximum system live load to the actual dead load, and that total will be the necessary minimum system capacity. Normally, you want to divide this total by the number of load cells and then go up to the next largest size available load cell.

Load-Cell-Kits-2Example: A tank has an empty weight of 22,000 pounds and an anticipated live load of 100,000 pounds for a total combined load of 122,000 pounds. Using four load cell stands, each cell will be seeing 30,500 pounds of anticipated weight. We would normally use a 50,000 pound load cell in this application. Since many times these systems are under a continual long-term load it is not uncommon for load cells to be almost twice the necessary capacity in order to help reduce signal creep.

Load-Cell-Kits-3Installation of load cell kits begin by determining if the floor (in the case of stand assemblies) or the building structure (for tension systems) is strong enough to bear the anticipated load. If not, piers or footings may be needed or additional support structures added. For all overhead suspension type systems, safety chains must be provided locally to bear any anticipated load due to component failure.

After the system is assembled, it is necessary to make sure that all of the load cells are taking equal dead load to the extent that it is possible. After the millivolt readings are as close as possible, secure the load cell stand assembles. Grouting the stands in place is the preferred method for long-term accuracy.

Most Cardinal Scale load cell stand kits come with checking designed into the stand itself. Depending on the device, some applications may require additional checking. Consult Cardinal Engineering for job specific requirements. Mixers and blenders are examples of devices that may need additional checking. Also, very tall tanks or hoppers may require additional restraints due to wind load on the structure.

Load-Cell-Kits-4Many systems using load cell kits require the connection of electrical supply or control wiring, as well as pipes and supply augers. Discharge chutes or pipes are used to get material out of the tank or hopper. It is very important to understand that anything connected to the scale-born structure must be installed with flexible couplings so that no path is present for force to be shunted off to ground during the weighing process. The more items that are connected to the structure the harder it is to get accurate weights.

Learn More:

Cardinal Scale Mfg. Co. • Ph. (800) 441-4237 • • 203 East Daugherty St., Webb City, MO 64870USA MANUFACTURER

Please Login to View Your Account

Create an Account

Click here to register.

Forgot Your Username or Password?

Click here to retrieve your account details.

Forgot Your Password?

Please enter your username or email address. You will receive a link to create a new password via email.

Quick Quote

  • This field is for validation purposes and should be left unchanged.